Skip to main content

Release Notes

General

This version of the connector requires OpCon version STS 20.7 or LTS 21.0 or greater.

WebServices 21.3

During the upgrade process, both the Connector and the EM Plugin must be upgraded.

The Communication Settings value Requires XML Escape Sequences of the Windows Agent that the Webservices Connector is associated with must be set to True.

CONNUTIL-623
Add new configuration check to allow property updates on failure.
Includes new configuration option UPDATE_PROPERTIES_ON_FAILURE

                [GENERAL]
DATA_DIRECTORY=
USES_PROXY=False
UPDATE_PROPERTIES_ON_FAILURE=False
DEBUG=False

CONNUTIL-624
Add new LF or CRLF selection when uploading message body information from file during POST & PUT requests as Windows expects CRLF and Unix/Linux expects LF for record termination. The default value is set as CRLF. CONNUTIL-625
Add the capability to extract the contents of an array item returned in a JSON structure. When using this, the JsonPath value should end in the required array value (i.e $.stats.[0]). CONNUTIL-626
Corrected a problem when single quote characters are used in the JSON message body. The single quote character is escaped by the Enterprise Manager plugin and then reverted by the Webservices connector prior to execution.

WebServices 21.2

Provides information on executing VisualCron Jobs to support RPA. Provides information on running WebServices Jobs as Windows Embedded Script jobs.

New Features

CONNUTIL-617
Added new parsing type TEXTSTRING to support the parsing of values returned from requests for VisualCron job variable values.
CONNUTIL-620
Added media type application/octet-stream to connector for POST and PUT requests.

Fixes

CONNUTIL-616
Fixed a problem where password information was displayed in the log files when DEBUG was enabled.

CONNUTIL-618
Fixed a problem when special characters are included in variable definitions causing an exception during variable replacement routines. CONNUTIL-620
Fixed a problem when doing a POST or PUT using a filename, the information was written into the msg body without CR+LF.

Upgrade Considerations

To implement the application/octet-stream media type selection, the Enterprise Manager WebServices sub-type must be updated.

Included information on using WebServices jobs as an Embedded Script for supporting VisualCron RPA jobs. Provided two script definitions in the templates section.