Defining Properties for Multi-Instance Schedules
When a schedule is marked as multi-instance and the Properties option is selected, OpCon builds one schedule instance for each property set you define. Each property set is a semicolon-delimited list of PropertyName=PropertyValue pairs.
To define properties for a multi-instance schedule, complete the following steps:
- Select Schedule Master under the Administration topic. The Schedule Master screen displays.
- Select the schedule in the Schedule Selection list.
- Select the Schedule tab in the Schedule Details frame.
- Select the Multi-Instance option in the Schedule Properties frame.
- Select the Instance Definition tab in the Schedule Details frame.
- Select the Properties option.
- Select the Build an instance for each set of Properties option.
- Enter a property set using the format
PropertyName=PropertyValue, separating multiple property pairs with a semicolon (;). For example:PName1=PValue1;PName2=PValue2. - Select Add.
- Repeat steps 8 and 9 for each additional instance.
- Select
Save on the Schedule Master toolbar.
- Select Close to close the Schedule Master screen.
Result: OpCon saves the property definitions. When the schedule is built, one instance is created for each property set.
note
You cannot clear the Multi-Instance option after property sets are defined. Remove all property sets before disabling multi-instance.