Job Output Retrieval System
The Job Output Retrieval System (JORS) allows users to view job output from the OpCon Enterprise Manager (EM). To activate JORS, configure both the LSAM and the EM.
Configure the JORS port in the EM
For the Enterprise Manager (EM) to connect to the LSAM for job output, configure the JORS Port Number to match the JORS Socket configured through the LSAM.
- Use menu path: Start > Programs > OpConxps > Enterprise Manager.
- In the Username text box, enter a case-sensitive User Login ID (e.g., ocadm) on the OpCon Login Screen.
- In the Password text box, enter the case-sensitive password for the user.
- In the Profile drop-down list, select the Profile.
- Click the Login button to log in to the Enterprise Manager.
- Double-click on Machines in the Navigation panel under Administration. The Machines screen displays.
- In the Select Machine list, select the LSAM machine.
- Right-click over the graphic to enable the menu in the Communication Status frame.
- Select Stop Communication from the menu.
- Click on Open Advanced Settings Panel in the Advanced Settings. The Advanced Machine Properties window displays.
- Click on the Communication Settings tab.
- Click the JORS Port Number parameter.
- In the frame below the advanced machine properties, enter the same value entered for the JORS Socket in the LSAM Configuration in the Modify Parameter frame at the bottom of the screen. For information on the JORS Socket in the LSAM configuration file, refer to JORS settings.
- Click the Update button.
- Click the Save button to save and close the Advanced Settings Panel.
- Right-click over the graphic to enable the menu in the Communication Status frame.
- Select Start Communication from the menu.
- Click on the x to the right of the Machines tab to close the Machines screen.
View Job Output in the EM
- Under the Operation topic, double click on List below the Navigation tab on the Enterprise Manager Screen.
- Click the plus sign (+) to expand the specific date.
- Click the plus sign (+) to expand the specific schedule.
- Right-click on the desired job.
- Click on View Job Output from the menu.
- Wait for JORS to retrieve the list of output files for the job in the Job Output Retriever window.
- Double-click on the Output File(s) name to retrieve the output file information.
- (Optional) Click the Copy To Clipboard button in the Log Viewer window.
- (Optional) Click the Open external editor button to open the file in an external editor (e.g., Notepad).
- Click the Close button to close the Log Viewer window.
- Click the Close button to close the Job Output Retriever window.