MSGIN
What is it?
MSGIN is a directory the SAP BW Agent watches for external OpCon events. Any external program or application can drop an ASCII text file into this directory; the agent reads the file, sends the contents to the SAM for processing, and then deletes the file.
Location: \<Configuration Directory>\SAP BW LSAM\MSGIN\ on the agent host.
The Configuration Directory is set during installation. For more information, refer to File Locations in the Concepts online help.
What goes in an MSGIN file
Each file must contain:
- A valid OpCon event command
- A User Login ID
- An external event password
If the SAM receives an invalid event, it discards the event and writes the message Invalid Event to the SAM Critical.log file.
Place a message in the MSGIN directory
To deliver an external event through MSGIN, complete the following steps:
-
Open an ASCII text editor (for example, Notepad) on the Windows host.
-
Enter the event text:
$JOB:RELEASE,[[$DATE]],ProdSched,ProdJob,BatchUser,EventPasswordNote the following requirements:
- The User Login ID and external event password go at the end of the event. The event password is not the same as the database password used to log in to the Enterprise Manager. Refer to External Events in the OpCon Events online help.
- The user must have the correct function privileges in OpCon for the SAM to perform the command.
- Allowable tokens are
$DATE,$TIME, and$NOW. These pull values from the current system date and time. - To send multiple events in one file, place each event on its own line.
-
Save the file in <Configuration Directory>\SAP BW LSAM\MSGIN\. The agent reads the file, sends the contents to the SAM, and deletes the file.
FAQs
Where do I put MSGIN files?
In \<Configuration Directory>\SAP BW LSAM\MSGIN\ on the agent host.
Can I send more than one event in a single file? Yes. Place each event on its own line. The agent reads the file, sends all events to the SAM, and deletes the file.
Why was my event ignored? The SAM discards events with syntactical errors and writes Invalid Event to SAM Critical.log. Confirm:
- The User Login ID is valid.
- The event password matches the configured external event password.
- The user has the required function privileges in OpCon.
Which tokens can I use in an event?